Contact us
Phone: +86-17725536523
WhatsApp: +8617725536523
North Development Zone, Sima Village, Sujiazhuang Town, Ningjin County, Xingtai City, Hebei Province, China
LV Aerial Bundled Conductor (ABC) Cables
- 产品描述
-
Application
Aerial Bundle Cable (ABC cable) is a very innovative concept for overhead power distribution as compared to the conventional bare conductor overhead distribution system.It provides higher level of safety and reliability, lower power losses and ultimate system economy by reducing installation, maintenance and operative cost.Caledonian LV Aerial Bundle Cables are designed to supply 600/1000 volt aerial service for temporary service at construction sites, as a service drop (power pole to service entrance), as a secondary cable (pole to pole) or street lighting.This over-head cable provides reinforced insulation acc. IEC 61140 and fulfill therefore Class II acc. IEC 61140. It is not flame retardant. But this could be if requested change to a flame retardant cable.
Standard
Basic design to BS 7870 / TNB Specification(IEC 60502) / HD 626 S1 / NFC 33-209 / AS/NZS 3560-1 standards

Construction
Conductor Aluminium conductor, round stranded compressed (RM). Insulation XPLE compound, UV-resistant. Core Identification 1, 2 resp. 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm² and a minimum of 16 ribs for cores above 50 mm². In the case of five core bundles the surface of the protective core should be smooth. Electrical Properties
Rated Voltage 0.6/1kV Test Voltage 4 Veff kV Minimum Laying Temperature -20°C Operating Temperature -40°C~ +90°C Maximum Short-circuit Temperature 250°C Maximum Conductor Temperature 80°C Minimum Bending Radius 18×OD Construction Parameters
BS 7870
Number of Cores x Nominal Cross Section
No.×mm²
Overall Diameter
mm
Weight
Kg/Km
Maximum Conductor Resistance
Ω/Km
Minimum Breaking Load
KN
Current Rating
A
1x16 RM 8.0 74 1.910 2.5 72 1x25 RM 9.0 106 1.200 4.0 107 1x35 RM 10.5 138 0.868 5.5 132 1x50 RM 11.8 182 0.641 8.0 165 1x70 RM 13.0 252 0.443 10.7 205 1x95 RM 15.4 333 0.320 13.7 240 1x120 RM 17.0 408 0.253 18.6 290 1x150 RM 19.0 502 0.206 23.2 334 1x185 RM 21.0 611 0.164 28.7 389 1x240 RM 24.0 801 0.125 37.2 467 2x16 RM 15.6 147 1.910 2.5 72 2x25 RM 18.0 208 1.200 4.0 107 2x35 RM 20.0 277 0.868 5.5 132 2x50 RM 23.5 361 0.641 8.0 165 2x70 RM 25.4 505 0.443 10.7 205 2x95 RM 30.3 666 0.320 13.7 240 2x150 RM 38.0 1004 0.206 23.2 334 4x16 RM 18.8 286 1.910 2.5 72 4x25 RM 21.2 430 1.200 4.0 107 4x35 RM 24.1 553 0.868 5.5 132 4x50 RM 27.8 746 0.641 8.0 165 4x70 RM 31.8 1009 0.443 10.7 205 4x95 RM 37.8 1332 0.320 13.7 240 4x120 RM 54.4 1632 0.253 18.6 290 4x50 + 1x25 RM 31.9 814 0.641/1.200 8.0/4.0 165/107 4x50 + 1x35 RM 31.9 845 0.641/0.868 8.5/5.5 165/132 4x70 + 1x25 RM 36.0 1105 0.443/1.200 10.7/4.0 205/107 4x70 + 2x25 RM 40.0 1217 0.443/1.200 10.7/4.0 205/107 4x95 + 1x25 RM 41.8 1438 0.320/1.200 13.7/4.0 240/107 4x95 + 2x25 RM 42.0 1544 0.320/1.200 13.7/4.0 240/107 4x120 + 1x25 RM 59.0 2050 0.253/1.200 18.6/4.0 290/107 Other cross-sections can be offered upon request.
TNB Specification(IEC 60502)
Number of Cores x Nominal Cross Section
No.×mm²
Overall Diameter
mm
Weight
Kg/Km
Maximum Conductor Resistance
Ω/Km
Minimum Breaking Load
KN
Current Rating
A
1x16+1x25 RM 15.3 160 1.910 2.5 72 3x16+1x25 RM 19.0 290 1.200 4.0 107 3x25+1x25 RM 23.2 400 0.868 5.5 132 3x35+1x25 RM 25.6 500 0.641 8.0 165 3x50+1x35 RM 30.0 680 0.443 10.7 205 3x70+1x50 RM 34.9 920 0.320 13.7 240 3x95+1x70 RM 40.6 1270 0.253 18.6 290 3x120+1x70 RM 44.1 1510 0.206 23.2 334 3x150+1x95 RM 49.2 1870 0.164 28.7 389 3x185+1x120 RM 54.9 2340 0.125 37.2 467 3x25+1x25+1x16 RM 23.2 470 1.910 2.5 72 3x35+1x25+1x16 RM 25.6 560 1.200 4.0 107 3x50+1x35+1x16 RM 30.0 740 0.868 5.5 132 3x70+1x50+1x16 RM 34.9 980 0.641 8.0 165 3x95+1x70+1x16 RM 40.6 1330 0.443 10.7 205 3x120+1x70+1x16 RM 44.1 1580 0.320 13.7 240 3x150+1x95+1x16 RM 49.2 1940 0.206 23.2 334 3x185+1x120+1x16 RM 54.9 2410 0.106 30.8 332 Other cross-sections can be offered upon request.
HD 626 S1
number of cores x nominal cross section
mm2
outer diameter
CA. mm
total weight
CA. kg/km
max. conductor-resistance
Ohm/km
min. breaking load of conductor strand
KN
current rating in the air 1)
A
2x16 RM 14.2 72 147 1.910 2.5 2x25 RM 17.2 107 208 1.200 4.0 2x35 RM 19.6 132 277 0.868 5.5 2x50 RM 22.4 165 361 0.641 8.0 4x16 RM 17.6 72 286 1.910 2.5 4x25 RM 20.3 107 430 1.200 4.0 4x35 RM 23.7 132 553 0.868 5.5 4x50 RM 27.1 165 746 0.641 8.0 4x70 RM 30.6 205 1009 0.443 10.7 4x95 RM 36.1 240 1332 0.320 13.7 4x120 RM 51.2 290 1632 0.253 18.6 4x35 + 1x35 RM 27.4 132/132 694 0.868/0.868 5.5/5.5 4x50 + 1x25 RM 30.5 165/107 814 0.641/1.200 8.0/4.0 4x50 + 1x35 RM 30.7 165/132 845 0.641/0.868 8.5/5.5 4x70 + 1x25 RM 34.8 205/107 1105 0.443/1.200 10.7/4.0 4x70 + 2x25 RM 38.7 205/107 1217 0.443/1.200 10.7/4.0 4x70 + 1x35 RM 36.0 205/132 1150 0.443/0.868 10.7/5.5 4x70 + 2x35 RM 38.2 205/132 1289 0.443/0.868 10.7/5.5 4x95 + 1x25 RM 40.2 240/107 1438 0.320/1.200 13.7/4.0 4x95 + 1x35 RM 42.1 240/132 1467 0.320/0.868 13.7/5.5 4x95 + 2x25 RM 40.9 240/107 1544 0.320/1.200 13.7/4.0 Other cross-sections can be offered upon request.
NFC 33-209
Number of Cores x Nominal Cross Section
No.×mm²
Overall Diameter
mm
Weight
Kg/Km
Maximum Conductor Resistance
Ω/Km
Minimum Breaking Load
KN
Current Rating
A
2x10 RM 12.8 93 3.080 1.5 38 4x10 RM 15.4 183 3.080 1.5 38 2x16 RM 14.8 129 1.910 2.3 72 2x16 RN + 2x1.5 RE 14.8 176 1.910/12.100 2.3 72 4x16 RM 17.8 257 1.910 2.3 72 4x16 RN + 2x1.5 RE 17.8 304 1.910/12.100 2.3 72 2x25 RM 18.0 202 1.200 3.8 107 2x25 RM + 2x1.5 RE 18.0 249 1.200/12.100 3.8 107 4x25 RM 21.7 404 1.200 3.8 107 4x25 RM + 2x1.5 RE 21.7 451 1.200/12.100 3.8 107 2x35 RM 20.8 269 0.868 5.2 132 2x35 RM + 2x1.5 RE 20.8 316 0.868/12.100 5.2 132 4x35 RM 25.1 539 0.868 5.2 132 4x35 RM + 2x1.5 RE 25.1 586 0.868/12.100 5.2 132 2x50 RM 23.4 352 0.641 7.6 165 2x50 RM + 2x1.5 RE 23.4 399 0.641/12.100 7.6 165 1x54.6 RM + 3x25 RM 21.7 507 0.630/1.200 3.8 107 1x54.6 RM + 3x25 RM + 1x16 RM 24.3 573 0.630/1.200/1.910 3.8/2.3 107/72 1x54.6 RM + 3x25 RM + 2x16 RM 29.7 639 0.630/1.200/1.910 3.8/2.3 107/72 1x54.6 RM + 3x25 RM + 3x16 RM 31.1 705 0.630/1.200/1.910 3.8/2.3 107/72 1x54.6 RM + 3x35 RM 25.1 615 0.630/0.868 5.2 132 1x54.6 RM + 3x35 RM + 1x16 RM 28.1 680 0.630/0.868/1.910 5.2/2.3 132/72 1x54.6 RM + 3x35 RM + 2x16 RM 34.3 748 0.630/0.868/1.910 5.2/2.3 132/72 1x54.6 RM + 3x35 RM + 3x16 RM 35.9 814 0.630/0.868/1.910 5.2/2.3 132/72 1x54.6 RM + 3x35 RM + 1x25 RM 28.1 714 0.630/0.868/1.200 5.2/3.8 132/107 1x54.6 RM + 3x50 RM 28.2 741 0.630/0.641 7.6 165 1x54.6 RM + 3x50 RM + 1x16 RM 31.6 806 0.630/0.641/1.910 7.6/2.3 165/72 1x54.6 RM + 3x50 RM + 2x16 RM 38.6 875 0.630/0.641/1.910 7.6/2.3 165/72 1x54.6 RM + 3x50 RM + 3x16 RM 40.4 940 0.630/0.641/1.910 7.6/2.3 165/72 1x54.6 RM + 3x50 RM + 1x25 RM 31.6 841 0.630/0.641/1.200 7.6/3.8 165/107 1x54.6 RM + 3x70 RM 33.0 950 0.630/0.443 10.2 205 1x54.6 RM + 3x70 RM + 1x16 RM 37.0 1014 0.630/0.443/1.910 10.2/2.3 205/72 1x54.6 RM + 3x70 RM + 2x16 RM 45.2 1083 0.630/0.443/1.910 10.2/2.3 205/72 1x54.6 RM + 3x70 RM + 3x16 RM 47.3 1148 0.630/0.443/1.910 10.2/2.3 205/72 1x54.6 RM + 3x70 RM + 1x25 RM 37.0 1048 0.630/0.443/1.200 10.2/3.8 205/107 1x54.6 RM + 3x70 RM + 2x25 RM 45.2 1150 0.630/0.443/1.200 10.2/3.8 205/107 1x54.6 RM + 3x70 RM + 3x25 RM 47.3 1250 0.630/0.443/1.200 10.2/3.8 205/107 1x54.6 RM + 3x95 RM 37.4 1176 0.630/0.320 13.5 240 1x54.6 RM + 3x95 RM + 1x16 RM 41.9 1243 0.630/0.320/1.910 13.5/2.3 240/72 Other cross-sections can be offered upon request.
AS/NZS 3560 Part 1
Number of Cores x Nominal Cross Section
No.×mm²
Overall Diameter
mm
Weight
Kg/Km
Minimum Breaking Load
KN
Current Rating
A
2x16 RM 15.0 140 4.4 78 2x25 RM 17.6 210 7.0 105 2x35 RM 19.6 270 9.8 125 2x50 RM 22.8 370 11.4 150 2x95 RM 30.6 680 15.3 230 3x25 RM 19.0 310 8.8 97 3x35 RM 21.1 410 9.8 120 3x50 RM 24.6 550 11.4 140 4x16 RM 18.1 290 8.8 74 4x25 RM 21.2 410 14.0 97 4x35 RM 23.7 550 19.6 120 4x50 RM 27.5 740 28.0 140 4x70 RM 31.9 1000 39.2 175 4x95 RM 36.9 1370 53.2 215 4x120 RM 40.6 1690 67.2 250 4x150 RM 43.9 2020 84.0 280 Other cross-sections can be offered upon request.